Preheater dimensions and number of cyclones stages are basically depends on kiln production capacity and the existence of precalciner and the amount of water that will be dried in the raw mill. -The design of the modern low -pressure cyclone has to fulfill the following requirement
High separating efficiency
The separation efficiency is proportional to the square of the
circumferential velocity, but inversely proportional to the radius of the
cyclone [usually the maximum
diameter of any given cyclone should not exceed 10 meter].
The low that explain the factors affecting separation in the
cyclone is as follows
Centrifugal force Z = m.u2/r
r : is the radius of the cylindrical part of the cyclone.