Preheater dimensions and number of cyclones stages are basically depends on kiln production capacity and the existence of precalciner and the amount of water that will be dried in the raw mill. -The design of the modern low -pressure cyclone has to fulfill the following requirement









 High separating efficiency 

      The separation efficiency is proportional to the square of the circumferential velocity, but inversely proportional to the radius of the cyclone [usually the maximum diameter of any given cyclone should not exceed 10 meter].

The low that explain the factors affecting separation in the cyclone is as follows

Centrifugal force Z = m.u2/r

             Where m is the mass of the particle that is carried by gas       ,

         u          : is the circumferential velocity of gas.

         r         : is the radius of the cylindrical part of the cyclone.